Wearable device for AV fistula remote monitoring shows promise—but faces commercial challenges

8261
SmartPatch

A new wearable device designed to remotely monitor arteriovenous (AV) fistulae function in dialysis access patients uncovered promising data leading one set of researchers to conclude the technology offers hope for improved care and lower costs among a challenging patient population.

The SmartPatch monitoring system (Alio Medical)—which involves the extraction of real-time data through a series of sensors from a patch placed over an AV fistula, subsequent cloud-based machine learning, and then actionable clinical alerts—is currently undergoing testing in a series of pilot studies aimed at tackling the healthcare burden of kidney failure and vascular access failure.

The first analysed dataset demonstrated the device “has the ability to measure haemoglobin, volumetric flow, and haemodynamically significant stenosis in AV fistulas,” Richard F Neville (Inova Heart and Vascular Institute, Falls Church, USA) recently revealed during the Society for Clinical Vascular Surgery (SCVS) annual meeting (13–17 March, Miami, USA).

Neville and colleagues looked at 128 patients at three dialysis centres, with all study participants wearing a SmartPatch device over an AV fistula either in the upper or lower arm.

“In this particular study, we utilised state-of-the-art optical technology with a particular patented array that allows for better data acquisition,” explained Neville, who disclosed that he serves on the scientific board of Alio Medical. “This took into account position, motion, light, temperature, and pulse of the patient. There was no need for patient interaction. This was all done remotely, and the clinical alerts are in real time.”

The intention of the study was to evaluate the ability of such a device to monitor AV fistula function, degree of stenosis, flow rate and the physiologic parameter of haemoglobin levels as a marker that impacts fluid management.

All participants wore a SmartPatch for a week. Each of the three clinical centres involved focused on one of the three metrics. The location focused on haemoglobin analysis studied 57 patients, the facility looking at volumetric flow looked at 21, and the centre monitoring percentage stenosis evaluated 71 study participants.

For each metric, Neville said, machine training algorithms were developed using the first 116 data streams from the device sensors. The algorithms were subsequently tested and correlated on the next 157 data streams, correlating with haemoglobin standard measurement, transonic flowmeters, and the standard fistulagram, he added.

The resulting data, Neville et al found, showed that haemoglobin was measured with comparative accuracy “and only a standard deviation of 0.41 as compared to haemoglobin measurement using standard techniques.”

The SmartPatch detected low volumetric flow—a potential indicator for access failure—with 100% sensitivity and 75% specificity, Neville continued. “Additionally, the degree of stenosis was also detected, looking at haemodynamically significant stenosis of great than 50%, with 100% sensitivity and 100% sensitivity as compared to subsequent fistulagrams, and arteriographic and angiographic imaging.”

He commented: “Therefore, we concluded in this study that this initial dataset shows us that this remote wearable monitoring system has the ability to measure haemoglobin, volumetric flow, and haemodynamically significant stenosis in AV fistulas. We are also hopeful that this remote monitoring system will allow us—and shows promise to allow us—to improve the care and lower the costs associated with other healthcare factors associated with this patient population.”

Neville said potential future biologic metrics that the device might monitor include oxygen saturation, blood pressure, heart rate, and haemoglobin and sodium levels.

Co-moderating the SCVS session in which Neville delivered his team’s findings, Jean Bismuth (Houston Methodist, Houston, USA) queried how placement of the patch might impact on the reliability of the data collected.

Neville explained that Alio had “spent a lot of time” on the material involved in the patch to ensure it is not injurious to skin, and that it can be used and worn for extended periods of time, among other considerations.

Meanwhile, W Charles Sternbergh (Ochsner Health, New Orleans, USA) who was co-moderating alongside Bismuth, raised the spectre of potential pitfalls toward commercialisation of the technology. Among Medicare patients, Sternbergh said, “evaluation of how their fistula is doing is baked in” to evaluation and management (E/M) services conducted at dialysis centres. “Typically, it is not allowed to have prophylactic testing, and it would even be suggested that that’s fraudulent, as some freestanding centres that do fistulagrams every three months no matter what have found out.”

Sternbergh asked: “How might this device intersect those issues?” Neville admitted this question got to the heart of the studied approach Alio has taken toward commercialisation.

“The technology has evolved rapidly,” he said. “When we first started this project in the animal lab, there was one sensor, a photo acoustic sensor. Now there is an array of sensors, and that is why we are able to generate the variety of information that I showed you.”

But, Neville continued, commercialisation remains an important step yet to be thrashed out. There are number of possibilities, he explained. One option might involve the device being given away for free, with an in-app-based subscription fee then applied for the data. Another would necessitate approaching dialysis companies with the benefits of keeping dialysis access fistulas functioning, and also keeping patients out of the emergency room, Neville said. “There were some initial cost savings shown in a dialysis population in the UK in the national health system [NHS] there, where just monitoring the haemoglobin accurately allowed [doctors] to adjust erythropoietin—which is a very expensive medication—and possibly decrease it, saving money just on the medications that are used on these folks.”

In the end, Neville added, he sees the device incorporated as a value-added part of care for the AV fistula patient population, as large dialysis companies realise close monitoring of access health and physiologic parameters “may actually save the overall cost of the patient in the long term.”


LEAVE A REPLY

Please enter your comment!
Please enter your name here